RV Awnings

RV Awning LED Lights Not Working

Quick answer

When RV awning LED lights stop working, check five things in this order. First the fuse, which Lippert puts on the red wire and says is usually behind the switch, 3 A maximum. Second, 12 volts at the strip's leads with the switch on. Third, the plug at the end of the roller tube, where the strip meets the feed wire. Fourth, water in the splices: one owner found corrosion at every splice, about every 2 feet. Last, the strip itself. To replace a strip, test the new one on a 9 V or 12 V battery first, cut it to the old strip's length on the nearest line, strip the wires 5/16 in, join them with bell caps or butt connectors color to color, and reseal where the wires enter the wall.

When RV awning LED lights stop working, check five things in this order, starting with the fuse, because Lippert wires the red lead "to a 3A maximum fuse (usually behind the switch)." Next, turn the switch on and measure for 12 volts at the strip's leads. If power reaches the leads, look at the plug at the end of the roller tube, where the strip joins the feed wire, and if only parts of the strip light, look for water in the splices. Only when all four check out is the strip itself dead, and then the fix is a new strip: test it on a 9 V or 12 V battery, cut it to length, strip the wires 5/16 in, join them with bell caps or butt connectors, and reseal.

Below are the terms, a table of what you see and where to look, each check in order, the replacement steps, a worked example and what owners found, and for the other parts of a power awning, see RV awnings.

What an awning LED light strip is

Awning LED light strip. A long, thin band of small LED lights that runs the width of an RV awning and lights the ground under it. It runs on the coach's 12 volt power through its own switch, separate from the awning motor, and Lippert's Solera manual shows two places it can sit. One is on the roller tube, the tube the fabric winds onto, so the light turns with the awning; the other is a light rail, a strip mounted on the side of the RV just below the awning rail, so the light stays put. Keystone's guide describes the strip as sliding into a track, and the replacement steps below work that way.

Leads. The two wires that feed the strip; on Lippert's wiring, red is power and black is ground.

End plug. On a roller tube light, the strip does not wire straight to the coach. Lippert's manual says to connect "the plug from the idler head" to "the plug from the LED light on the roll tube." The idler head is the end of the awning with no motor, so the strip has a plug at that end, and a feed wire comes down through the idler arm to meet it.

Splice. A joint inside the strip where two lengths of the circuit are soldered together, and water that reaches a splice corrodes it, and the lights past that point go dark.

IP65. A rating for how well a part is sealed against dust and water, and the label on the replacement strip Carefree sent one owner, described below.

RV awning LED lights not working: where to look

Each row is a ruling from the sections below, with its source named there.

Awning LED strip dark: what you see and what to check
What you seeLikely causeWhat to do
Whole strip dark, nothing at allFuse on the light circuitCheck the fuse behind the switch; Lippert's limit is 3 A
New fuse blows againA short in the strip or wiringLeave the circuit off and unplug the strip before testing more
Fuse good, no 12 V at the leadsSwitch or wiring between switch and armTrace back toward the switch with a meter
12 V at the leads, strip darkEnd plug loose, cracked or corrodedUnplug, clean, check the shell, plug back in firmly
Some sections lit, some darkWater and corrosion at splicesReplace the strip
Power at the plug, plug good, still darkStrip has failedReplace the strip

Check 1: the switch and its fuse

Start here when the whole strip is dark. Lippert's Solera manual says "the red wire is connected to a 3A maximum fuse (usually behind the switch)." For a light rail it says the same thing another way: it "must be wired through a 3A maximum fused circuit." So the fuse is often not in the main fuse panel but in the wire behind the light switch on the wall.

  1. Turn the switch off, then take the switch plate off the wall, ease the switch out and look for a small fuse holder on the red wire behind it.
  2. Check it. Pull the fuse and look at the metal link inside, or test it with a meter set to continuity if you cannot see the link clearly.
  3. Replace it with the same rating, which on a Lippert light is no more than 3 A.

On the Grand Design owners forum, one owner whose awning lights quit wrote that "the dealer replaced a fuse that is built in to the back of the light switch."

If the new fuse blows: stop there, because a fuse that blows again means current is going where it should not, so there is a short somewhere. Owners on the Heartland forum describe strips that shorted and "burned a pencil eraser size hole" in an awning, and LEDs that "burned holes in the fiberglass siding." Do not fit a bigger fuse; leave the switch off and unplug the strip at its end plug before you test further.

Check 2: 12 volts at the strip's leads

A good fuse does not prove the strip has power, so the next step is a meter check at the strip end of the wiring with a cheap multimeter set to DC volts.

  1. Open the awning. On a roller tube light, the feed wire comes down the idler arm. Lippert's install steps start with "Remove the wire covers in the idler side mount arm." On a light rail, Lippert runs the wire down through the drive side mount arm.
  2. Reach the leads. Take off the arm's wire cover, find where the feed wire meets the strip, and turn the light switch on.
  3. Measure. Put the red probe on the red (power) wire and the black probe on the black (ground) wire. You should read close to the coach's battery voltage, about 12 volts.

If you read nothing, the fault is somewhere between the switch and the arm, such as a bad switch, a broken wire or a loose ground. Check for power coming out of the switch first, then follow the wire toward the arm. If you read 12 volts at the leads and the strip is still dark, power is getting there and the problem is at the plug or in the strip.

Check 3: the end plug on the roller tube

On a roller tube light, power reaches the strip through the plug at the idler end, and that plug sits right at the end of the tube, where it turns each time the awning opens and closes.

  • Pulled apart. Make sure the two halves are pushed or screwed fully together.
  • Cracked or crushed. Look for a split or flattened shell, or a wire pinched where it leaves the plug.
  • Corroded. Look for green or white crust on the pins.

Unplug it, clean the pins if they are dirty, plug it back in firmly and test again. A cracked or crushed plug needs replacing, and Lippert sells its roller tube Vista Light strip, in 15 or 20 foot lengths, with a connector that joins "the idler head slip disc or the wiring in the fabric (drive side)." So a new strip brings a new plug with it.

Check 4: water in the splices

If some of the strip lights and some does not, power is reaching it, so the fuse and feed wire are fine and the fault is inside the strip, and water is a common cause.

The clearest case is a thread on the Heartland owners forum. An owner of a 2018 Road Warrior 426 wrote that about two thirds of the lights on the front awning were out. When the strip came out, the owner found that "at every splice (appx 2') there was corrosion. At the connector end there was corrosion and a small hole in the strip."

The fix was not a repair. Carefree, the awning maker, sent a new strip labeled "IP65 waterproof," even though the old one was out of warranty, and the owner wrote that "the install was very easy." So once you find corrosion at the splices, plan on fitting a new strip rather than cleaning the old one.

Check 5: the strip has failed

If there is 12 volts at the plug, the plug is clean and whole, and the strip is still dark, the strip has failed. LED strips can also fail without water: one Heartland owner said rope type lights "just flame out, and have to be replaced." Another said a replacement from the RV maker "too burned out." Any strip with scorch marks or melted spots goes in the trash, not back on the awning, whatever else you find.

Before you buy one, check whether you need a strip or a kit, because a strip only fits an awning that already has the track and wiring. On a Solera, etrailer's listing for Lippert's LED light kit with switch (LC674283) says it needs PrepFlex fabric with the track built in, so an awning without that track needs the kit, not just a strip. For adding lights to an awning that never had them, see RV awning accessories. If the light is wired into the fabric seam instead of a track, see the owner reports below.

How to replace the LED strip

These steps follow Keystone RV's own guide, which lists these tools: a screw gun with a #2 square bit, shop towels and gloves, a putty knife, adhesive remover or alcohol, a caulk gun and sealant, wire strippers and crimpers, bell caps or butt connectors, and a ladder.

  1. Turn off the power. Keystone says: "Always turn off the power to the light before starting."
  2. Unroll the awning fully to reach the whole strip, then take the cover off the hardware where the wires run.
  3. Remove the old sealant. Scrape off any silicone holding the strip in place.
  4. Cut the old wires. Cut the two wires closest to the strip, keep track of which is which, and slide the old strip out of its track.
  5. Cut the new strip to length. Lay it beside the old one and cut "on the nearest line," the cut marks printed on the strip.
  6. Test the new strip. Before it goes in, touch its leads to "a 9-volt battery or your RV's 12-volt battery" and make sure it lights.
  7. Slide it into the track where the old strip came out, then strip the wire insulation "about 5/16 inch," as Keystone says.
  8. Join the wires. Use bell caps or butt connectors, "matching the wire colors"; Lippert's rule is red to the power wire and black to the ground wire.
  9. Reseal. Keystone says to caulk where the wires enter the wall "to prevent moisture intrusion." Lippert says to seal "all fastener locations and wire penetrations." On a light rail, Lippert also seals the back of the rail with silicone or butyl tape.
  10. Put the cover back and test.

On fit: etrailer lists Lippert's replacement strip LC423331 as 20 feet long and says it "can be trimmed." It replaces the flat track LED strip on Solera awnings, and when an owner of a Cedar Creek 38EL asked about its thickness, etrailer's answer was that the strip is "extremely thin" and that the housing opening they checked was "about 1/16 of an inch." So measure your old strip and the opening of your track before you order a replacement.

Worked example: a strip with dark sections

Take an 18 foot Solera power awning with a light on the roller tube. Suppose the switch is on and only the first few feet light up, while the rest stays dark.

Step 1: read the symptom. Part of the strip lights, so power is reaching it, which rules out the fuse and the feed wire, so skip checks 1 and 2.

Step 2: check the end plug. Open the awning, take off the idler arm's wire cover, and look at the plug. Say it is tight and clean, which points inside the strip.

Step 3: look at the strip. Slide it out of the track, and suppose there is green crust at the splice where the light stops. That is the Heartland case, water at a splice, and the strip needs replacing.

Step 4: size the new strip. A 20 foot LC423331 covers an 18 foot awning. Lay it beside the old strip and cut on the nearest line.

Step 5: fit it. Test it on a 9 V battery first, then slide it in, strip the wires 5/16 in, join red to red and black to black, and seal where the wires enter the wall.

What owners found

A wire sewn into the fabric. On the Grand Design forum, the owner of a 2022 Solitude 390RK took the coach to a dealer because the awning bar light would not come on. The dealer said "the wire that is sewn into the awning is bad" and that the only fix was a new awning. Other owners disagreed, and one wrote that the wire in the seam "can be pulled out and replaced with like size wire," taping "a string or new wire to the end of the old wire before pulling it out," then using solder or "water proof wire cramps." Another suggested a stick-on strip on the side of the coach, wired into the old feed. If your light is fed this way, those are the choices before replacing the fabric. For fabric jobs, see RV awning fabric replacement.

Lights that flash once and go out. One owner on RVUSA's forum wrote: "When I turn the switch on, they flash once and then go out." No one posted a fix, but a strip that flashes shows that power got to it at least once, so start at the end plug and the splices rather than the fuse.

A strip inside the roller. On RVForums, an owner tried to reach bad LEDs inside the roller tube itself. The end caps were riveted and there was a spring inside, and another owner who had replaced several warned: "The spring can hurt you." That is a different job from sliding a strip out of a track.

What this answer does not cover

The checks and steps here come from Lippert's Solera manual (CCD-0001261, rev 03.16.18), Keystone's replacement guide and etrailer's and Lippert's listings. They fit strips that slide into a track on the roller tube or a light rail. They do not cover lights wired through the fabric seam beyond the owner reports above, or strips mounted inside the roller tube, where the awning's spring is under tension. Leave those to a dealer. The 3 A figure is Lippert's, and other makers may use a different fuse, so check your switch or manual. A fuse that keeps blowing, or any scorch mark on the strip, the fabric or the siding, means a short, so fix the cause before the light goes back on. If the awning motor or its switch also misbehaves, that is a different circuit, covered in RV awning motor problems. A coach still under warranty should go to the dealer first, since Carefree replaced one owner's strip at no cost.

If the light rail sits right under the awning rail, a poor seal behind it can let water into the wall. For that, see RV awning rail leaking.

Key takeaways

  • Check in order: fuse behind the switch, 12 V at the strip's leads, the end plug, water in the splices, then the strip.
  • Lippert's fuse is 3 A maximum on the red wire, usually behind the switch, and a fuse that blows again means a short, so stop.
  • Part of the strip lit means power is there, so look for corrosion at the splices; one owner found it about every 2 feet.
  • Test a new strip on a 9 V or 12 V battery before fitting it, cut it on the nearest line, strip the wires 5/16 in, and join color to color.
  • Reseal every wire and fastener hole, as Keystone and Lippert both say, to keep water out of the wall and the strip.

Frequently asked questions

Where is the fuse for RV awning lights?

On a Lippert Solera, the manual says the red wire goes to a 3 A maximum fuse "usually behind the switch." Take the switch out of the wall and look for a small fuse holder on the red wire. Other makers may put it in the main fuse panel.

Why do only some of my awning LED lights work?

Power is reaching the strip, so the fault is inside it, and water at a splice is a common cause. One owner found corrosion at every splice, about every 2 feet, and a small hole at the connector end. The fix is a new strip.

Can I test an awning LED strip with a 9 volt battery?

Yes. Keystone's guide says to test a new strip with "a 9-volt battery or your RV's 12-volt battery" before installing it. Touch the red lead to the positive terminal and the black lead to the negative terminal.

Can you cut an RV awning LED strip?

Yes, on the cut lines printed on it. Keystone says to measure the new strip against the old one and cut "on the nearest line." Lippert's LC423331 replacement is 20 feet long and can be trimmed.

How much wire do I strip to connect a new awning light?

Keystone says about 5/16 inch. Join the wires with bell caps or butt connectors, matching colors, then caulk where they enter the wall.

Sources and further reading