Dometic 9100 Power Awning Won't Retract
Quick answer
When a Dometic 9100 power awning won't retract, check the motor fuse, the battery and the ignition interlock first. If the LED light strip lights but the motor does nothing, suspect the motor fuse, because Dometic puts the LEDs on a separate circuit. The current install manual puts a 15 A fuse on the awning switch and a 5 A fuse on the LED switch. On a motorhome, a working interlock cuts awning power while the ignition is on, so turn the key off. If you still have to close it by hand, Dometic gives two methods in order. First, Auxiliary Power: a 12 V car battery, 16 gauge leads with a 3 A in-line fuse, plugged into the motor connector in the upper right arm, black to black and red to red. Reversed leads extend it. Second, the Pull Strap: two people, the strap in the roller tube's utility slot, and two screws out of the right top casting while the spring winds it in. After either one, Dometic says the awning needs a qualified service technician.
When a Dometic 9100 power awning won't retract, check three things before anything else: the awning motor's fuse, the battery and, on a motorhome, the ignition interlock. A quick test tells you where to start. If the awning has an LED light strip and it lights up but the motor does nothing, check the motor fuse. Dometic puts the LED strip on a separate circuit from the motor, so working lights prove the battery is there but say nothing about the motor's fuse. If you still cannot get it in, Dometic gives two ways to close it by hand, to be tried in this order. First, run the motor straight off a 12 volt car battery. If that fails, roll it in with the pull strap, which takes two people. After either one, Dometic says the awning needs a qualified service technician.
Below are the terms, a table of what you see and what to do, the checks in order, both manual-close methods step by step, a worked example and what this page does not cover. If your awning is not a 9100, start with RV awning won't retract.
What a Dometic 9100 is, and the words that matter here
Dometic 9100. A 12 volt power patio awning for RVs, sold by Dometic, whose US awning line grew out of A&E Systems. It is an open roller awning, not a box. The fabric winds onto a long tube, and two arms hold the tube out from the side of the RV. A motor turns the tube, and a spring inside the tube pulls it closed. Dometic's manual says the tube is "under spring tension, which will attempt to close the awning quickly." That spring matters later, when you close it by hand. For the brand's other models, see Dometic RV awnings.
FRTA. Dometic's name for the fabric roller tube assembly: the tube, with the fabric wound on it. It has a slot along its length, which Dometic calls the utility slot. The pull strap goes in there.
Right-hand arm. The motor end. Dometic's install manual says "the motorized arm assembly is always installed at the right-hand side of awning," and that arm comes pre-wired for the motor.
Motor connector and hardware connector. Two plugs that join in the upper part of the right-hand arm. The motor connector comes from the motor. The hardware connector comes from the RV's wiring. Pull them apart and the motor is cut off from the coach.
Top casting. The metal piece at the top of each arm, where the arm meets the roller tube. Two screws in the right-hand one hold the tube against its spring.
Ignition interlock. A safety cutout on motorhomes. It cuts power to the awning whenever the ignition is on, so the awning cannot open while you drive. Dometic's install manual says not to fit a 9100 to a motorhome without one.
Dometic 9100 won't retract: what you see and what to do
Each row is a ruling from the sections below, where its source is named. The rows about clicks and slow retraction come from owner reports, not from Dometic.
| What you see | Likely cause | What to do |
|---|---|---|
| LED strip lights, motor silent | Motor fuse | Check the awning motor's fuse at the fuse panel or converter |
| LED strip dark too, motor silent | No 12 V power | Check the battery, the battery switch and shore power |
| Motorhome, motor silent | Ignition on, so the interlock has cut power | Turn the ignition off and try again |
| Click or clunk, no movement | Low voltage, a dirty plug, or a hot motor | Charge the battery, clean the motor plug, or wait and retry |
| Retracts slowly or labors | Weak roller spring or a weak supply | Plug in; have a dealer check the spring tension |
| Pitch arm will not slide | Adjustable knob too tight | Loosen both knobs so the arms reset, then retract |
| None of these, you need it in now | Power or motor failure | Auxiliary Power method first, then the Pull Strap method |
| Car battery runs it, coach switch does not | Fault in the coach wiring or switch, not the motor | Close it, leave it unplugged and book a technician |
First checks: fuse, battery and the LED test
Dometic's manual says to "rule out simple causes for power failure" before you close the awning by hand. It lists four: the RV disconnected from power, a blown fuse, a low or flat battery, and the ignition interlock. It also gives the quickest test of the lot. The LED light strip, if your awning has one, "is on a separate circuit from awning motor." So if the LEDs work but the motor does not, Dometic says to check the motor's fuse "at fuse panel or converter" first.
The install manual shows why the test works. The current edition (rev L, 2023) puts a 15 A fuse on the red wire that feeds the awning switch. The LED switch gets its own 5 A fuse, and the interlock's pink wire gets another 5 A fuse. An older edition (rev E, 2018) gives 3 A for those two smaller fuses. The motor fuse is 15 A in both. Three fuses means the LEDs can work while the motor fuse is blown.
If the LEDs are dark as well, the problem is further back. Look at the battery, the battery disconnect switch and the shore power cord. If the fuse looks fine and the battery is charged, trace the power from the battery to the switch. RV awning motor problems walks through that with a meter. When a new fuse blows again at once, stop fitting fuses. Something is shorted, and a bigger fuse only hides it.
On a motorhome: the ignition interlock
A motorhome's 9100 should be dead whenever the ignition is on. That is the interlock doing its job. So if the awning will not come in while the engine runs or the key is on, turn the key off and try again before you suspect anything else.
Dometic also wants the interlock tested before every trip. This test only applies to motorhomes. With the awning fully closed:
- Turn the ignition on and try to open the awning.
- If it stays closed, the interlock works. You are done.
- If it opens, the interlock has failed. Close the awning, then pull the fuse that feeds it and test again.
- If it still moves, pull the motor connector off the hardware connector. Dometic says the plug can be hard to reach with the awning closed, so pull the wiring at the right-hand top casting until the wires come apart. Test once more.
- Have it repaired by a qualified service technician before you travel.
Dometic is plain about the stakes. If the awning answers the switch with the ignition on, "accidental operation during transit could occur." If yours has ever opened on the road, see RV awning opened while driving.
It clicks or clunks but does not move
Dometic's manuals do not list this symptom, so what follows comes from owners. Read it as reports, not as Dometic's rules.
On a Grand Design owners' forum in 2019, an owner's 9100 would give "a click by the awning motor" and the lights in the slide would dim, but it would not move. A new switch and new fuses did not help. Another member said "if it is clicking that's not a good sign for the motor." It turned out not to be the motor. The owner fished out the motor plug with a coat hanger, ran the awning from a battery charger cord, and found "a loose/weak/dirty connection." Contact cleaner fixed it. Months later the same owner said the fault came back on hot, sunny days. They guessed the wire to the motor was too small, and in the end the dealer replaced the motor and the switch.
On a Heartland owners' forum in 2009, a 9100 gave "something like a 'clunk'" on retract and nothing else. The owner waited, tried again, and it rolled up. A reply pointed out "there is a thermal cut off that will prevent it from moving." The same thread passed on what Heartland told another owner: the motors are low torque, and in strong wind the awning may stall "until the wind calms down."
So a click with no movement can be a weak supply, a dirty plug at the motor, or a hot motor. Charge the battery, let the motor rest and try again. The motor plug is the one in the upper right-hand arm. If you can reach it, look for green or white corrosion on the pins.
It retracts slowly, or labors on the way in
The spring in the roller tube pulls toward closed, so it helps the motor on the way in. In the same Heartland thread, an owner said their 9100 "was really slowing down when retracting." The dealer "tightened up the spring inside of it and that solved the problem." The spring sits inside the roller tube and is wound at the factory. Dometic's install manual warns that removing the cotter pin "will release the factory preset torsion (spring) tension." Leave spring work to a dealer.
Low voltage also slows a motor. Plug into shore power or start the generator and try again. If it closes at normal speed, the battery was the cause.
One more thing to check before you blame the motor. Dometic's normal close steps start with the two adjustable knobs on the lower arms. Loosen them so the awning resets to its original position, then tighten them lightly. Pull down on the top arm to check. The pitch arm "MUST still slide as normal." A knob left tight on an arm you lowered to shed rain can hold the awning back.
Getting it closed now: Dometic's two methods
Dometic's manual says to do the Auxiliary Power method first. Only if that fails do you move on to the Pull Strap method. Both start the same way:
- Reset the arms. Loosen the adjustable knobs so the awning returns to its original position, then tighten them lightly.
- Cut the power. Disconnect 120 volt power from the RV and 12 volt power to the awning. Dometic warns that a fault can look like a power failure while current is still there, or power "may return unexpectedly."
- Unplug the motor. Pull the motor connector off the hardware connector, in the upper part of the right-hand arm.
Method A: Auxiliary Power (a car battery)
This runs the motor straight from a battery and skips the coach's wiring, switch and fuses.
- Get a 12 volt car battery and two wire leads of 16 gauge or heavier. Dometic says the leads are user supplied.
- Fit a 3 A in-line fuse on the lead that will go to the positive (+) terminal. Dometic says that lead "MUST" have one.
- Connect the leads to the motor connector and tape them in place with electrical tape. Match the colors: black to black, red to red. Do not connect them to the hardware connector.
- Connect the other ends to the battery: red to positive (+), black to negative (-). The awning should start to retract.
- Disconnect the moment it is closed. Dometic says to cut the power "IMMEDIATELY" once it retracts, or the motor can be damaged.
If the awning goes out instead of in, the leads are reversed. Dometic says plainly, "The awning will extend if wire leads are reversed." Swap them at the battery. If it runs on the car battery, the motor works. The fault is then somewhere between the coach battery and the motor plug, such as the fuse, the switch or the wiring. If it does not move at all, check your connections and the battery's charge. If it still does nothing, Dometic says "the motor may be defective." Go on to Method B.
Method B: the Pull Strap
This uses the roller tube's own spring to wind the awning in, with a person holding it back. Dometic says you need a 5/32 in hex key and "help from at least one other person." Several Heartland owners said their RVs came without the pull strap, so check that you have one before you need it.
- Check the knobs and the plug. The adjustable knobs should be only lightly tight, and the motor connector unplugged.
- Put the strap in the utility slot of the roller tube and slide it to the center.
- One person grips the strap firmly. Then the other removes the two screws at the top and back of the right-hand top casting. Keep the screws.
- Let it roll up slowly. The person on the strap walks it diagonally, to the left or right, as the awning rolls up. Otherwise the fabric can crease or bulge and stretch for good.
- Put the two screws back before you move the RV. Line up the holes in the right-hand top casting and refit them. Without them, Dometic warns, the awning "could extend quickly and unexpectedly during transit."
- Leave the wiring unplugged. Dometic says "Do NOT reattach wiring."
The spring does the work, so hold on. The moment those two screws come out, the spring in the roller tube tries to close the awning "quickly and unexpectedly." Keep clear of the arms as they fold against the back channel, since both are pinch points. This is why a 9100 is not like a Lippert Solera, whose manuals say the motor holds the awning still. On a 9100, the spring is pulling it closed the whole time. For other makers' overrides, see awning manual override and Lippert Solera awning won't retract.
After a manual close: a technician, not a fix
Both methods get the awning in. Neither one repairs it. Dometic's manual says: "After awning is closed manually, it will require service by a qualified service technician." That fits what the methods do. Method A leaves the motor unplugged from the coach. Method B leaves the wiring off on purpose. Do not plug it back in and try the switch to see what happens. A Heartland owner said the same thing: you can close it by hand, "but you have to have it serviced after you do that."
Worked example: stuck out at the campsite, LEDs on
Take a fifth wheel with a 9100 and an LED strip, the evening before you leave. Suppose you press retract and the motor is silent: no click, no hum.
Step 1: flip the LED switch. Say the strip lights. The LEDs are on their own circuit, so the battery is there and the problem is on the motor side.
Step 2: open the fuse panel and find the awning fuse. In this case it has blown. Fit a new 15 A fuse and try again. If the awning comes in, you are done, but watch for the next blown fuse.
Step 3: suppose the new fuse blows the moment you press the switch. That points to a short, so stop fitting fuses. It is a fifth wheel, so the interlock test does not apply.
Step 4: close it with Method A. Shut off shore power and the awning's 12 volt feed. Loosen the knobs, unplug the motor connector in the right-hand arm, and run 16 gauge leads from it to a car battery, with a 3 A in-line fuse on the red lead. Black to black, red to red. Suppose the awning comes in. Disconnect at once.
Step 5: read the result. If the motor runs on the car battery, the motor is likely fine and the fault is in the coach's wiring or switch. Leave the motor unplugged, as Dometic says, and book a technician.
When to call a technician or Dometic
Dometic's answer for any fault the manual cannot fix is "a qualified service technician." Its support line, from the install manual, is 1-800-544-4881. Call when:
- You have closed the awning by either manual method.
- A new motor fuse blows again.
- The motor does not run even on a car battery.
- The ignition interlock test fails on a motorhome.
- The awning labors on the way in and you suspect the spring.
What this answer does not cover
The steps here come from Dometic's 9100 operation manual (rev C, 2019) and the 9100 install manual. They do not cover the Dometic 9200 or 9500 or older A&E models, or awnings with a wind sensor or a control box. Those close in different ways. Dometic's manuals give no voltage figure for the motor and no cool-down time for the thermal cutout, so this page gives neither. The click, clunk and slow-retract rows come from owners, not from Dometic. Method B releases a wound spring with real force behind it. If an arm is bent, the fabric is torn, or the awning is loaded with water or wind, do not try it. Get a technician. Never drive with the awning out, or with the top casting screws left out. An awning still under warranty should go to the dealer before you open anything up.
Key takeaways
- LEDs on, motor dead: check the motor fuse. The LED strip is on its own circuit. The motor fuse is 15 A.
- On a motorhome, turn the ignition off. A working interlock cuts awning power while it is on.
- Click with no movement: owners have traced it to low voltage, a dirty motor plug or a hot motor.
- Close it by hand in Dometic's order: car battery first (16 gauge leads, 3 A in-line fuse, black to black, red to red), then the pull strap with two people.
- After a manual close, leave the wiring unplugged and have a qualified technician service it.
Frequently asked questions
How do I manually retract a Dometic 9100 awning?
Cut 120 volt and 12 volt power and unplug the motor connector in the upper right-hand arm. Then run the motor from a 12 volt car battery with 16 gauge leads, black to black and red to red, with a 3 A in-line fuse on the red lead. If the motor does not run, use the pull strap method with a helper. Either way, have a technician service it afterward.
Why do my awning lights work but the awning won't move?
Dometic puts the LED light strip on a separate circuit from the motor. Working lights prove the battery is there but not that the motor fuse is good. Check the awning motor's fuse at the fuse panel or converter.
What size fuse does a Dometic 9100 awning use?
The install manual puts a 15 A fuse on the red wire that feeds the awning switch. The LED switch and the ignition interlock get their own smaller fuses: 5 A in the 2023 manual, 3 A in the 2018 one.
Why did my awning open when I connected a battery?
The leads are reversed. Dometic says the awning extends if the polarity is reversed. Disconnect, swap the leads at the battery, and connect again.
Does a Dometic 9100 have a spring?
Yes. Dometic says the roller tube is under spring tension that tries to close the awning quickly. The pull strap method uses that spring, which is why one person must hold the strap before the screws come out.
Can I reconnect the motor after a manual close?
Dometic says no. After the pull strap method it says "Do NOT reattach wiring," and after either method the awning needs service by a qualified technician.
Sources and further reading
- Dometic: 9100 Series Power Patio Awning Operation Manual, Form 3312736.048 Rev C 11/19 (simple causes, LED circuit, interlock test, Auxiliary Power and Pull Strap methods; hosted by Forest River)
- Dometic: 9100 Power Patio Awning Installation Manual, Form 3312737.054 Rev L 2023-07-20 (fuse ratings, interlock requirement, right-hand motor arm, spring tension, support line)
- Dometic: 9100 Power Awning installation manual, Form 3316039.000 Rev E 1/18 (earlier 3 A ratings for the interlock and LED fuses)
- Heartland Owners Forum: Electric awning won't retract (August 2009; 9100 clunk, thermal cutoff, slow retract fixed by spring tension, missing pull straps)
- myGrandRV forum: Dometic awning won't extend (August 2019 to January 2020; 9100 click traced to a dirty motor plug)
How we write our guides: figures are typical US ranges checked against manufacturer documentation, published standards and installer pricing. Read our editorial standards. Spotted an error or outdated detail? Request a correction.